肥水不落旁人田淑芬,最新国自产拍

customer service hotline
88315192 0791- 88315192

Home > Business scope > Main business

Power Saving and Control

2016-05-01 Reading volume: 4123 2016-05-01

system introduction
SL-ZPL-1000 electric energy-saving intelligent control system is to install a series of power sensors at the distribution user terminal, monitor various types of power instruments and relay protection circuits, collect data to the user's local server through various communication protocols, and then pass 4G The wireless router is transmitted from the mobile wireless network to the cloud service platform of the company's data storage center. On the cloud service platform, a large number of data processing operations such as mathematical modeling and energy consumption analysis of the user's power data and power consumption status are performed; The data and calculation result parameters are sent to the customer's mobile APP and user computer; forming a complete system link; thus providing managers and technicians with real-time online power monitoring, fault prediction, fault alarm, and power consumption analysis, Power management assessment, etc., to meet user requirements for power monitoring.

The difference between SL-ZPL-1000 power energy saving intelligent control management system and its traditional SCADA management system



SL-ZPL-1000 Design Standard for Intelligent Energy Management Control System

ISO50001 ISO50001

GB/T23331-2012 GB / T23331-2012

DL T645 2007 DL / T645-2007

ISO/IEC11801 ISO / IEC11801

GB/50198 GB / 50198

GB50052-2009 GB50052-2009

GB50054-2011 GB50054-2011

DL T5103 DL / T5103

GB50059 GB50059

NDG889 NDG889

GB50229-2006 GB50229-2006

Energy management system

Energy management system requirements

Multifunctional Energy Meter Communication Protocol

合布线标准 International Integrated Wiring Standard

Monitoring system engineering technical specifications

Design specifications for power supply and distribution systems

Design specifications for low-voltage power distribution

无人值班变电所设计规程 35-110 KV unmanned substation design code

变电所设计技术规程 35-110 KV Substation Design Technical Regulations

Technical regulations for the design of secondary wiring in thermal power plants and substations

Design of fire protection conditions for thermal power plants and substations


SL-ZPL-1000 Electric Energy Saving Intelligent Control Management System Application Scope
SL-ZPL-1000 electric energy-saving intelligent control system is widely applicable to large-scale public buildings, commercial squares, industrial and mining enterprises, hotels, hospitals, real estate, governments, schools, and other power users from 0.4KV to 110KV voltage levels.

Advantages of SL-ZPL-1000 Electric Energy Saving Intelligent Control Management System
◆ High level of power management automation
SL-ZPL-1000 electric energy-saving intelligent control management system automatically collects and detects all electrical energy data around the clock, and provides a panoramic view of the mobile phone screen. It replaces the traditional monitoring SCADA operation duty to achieve unattended and safe operation. Through continuous protection and monitoring of the user's power distribution network and electrical equipment, it improves the reliability of power supply and the automation level of the power supply system.
SL-ZPL-1000 electric energy saving intelligent control management system collects electric energy data and stores it on the cloud platform. The data is stored for 5 years and can be checked and printed. From the traditional passive monitoring of personnel, to the evolution of active continuous monitoring in the cloud, to improve the monitoring intensity and prevent accidental electrical failures. At the same time, in cooperation with the offline repair team, a full-time non-professional staff will be employed to guard and call the maintenance unit in case of accident. In order to use professional processing for a short period of time, improve the efficiency of fault handling, and save labor costs; In addition, the system converts human experience into an expert system, and uses a system platform instead of manual to perform basic, repetitive, and big data analysis, which not only expands experience The scope of services also reduces the cost of professional services.


◆ Convenient power management for corporate users
SL-ZPL-1000 Electricity Energy-saving Intelligent Control Management System automatically forms electric energy minute, hour, day, month, and year curve data in the cloud data, automatically analyzes and models, performs automatic inspection, automatically locks fault points and alarms, and can process in time. Reduce the impact of failures on corporate production. The system's functions are not limited by location and time. The mobile phone displays, analyzes, and alarms on-line. It becomes an enterprise power management and control center, allowing users to achieve "one machine in hand, energy-saving and worry-free."
SL-ZPL-1000 electric energy-saving intelligent control management system adopts digital fault indicator and digital communication technology. It is mainly used in the customer's power distribution room power transmission and distribution system. The system can monitor line short circuit, grounding, overload, and disconnection. Lines, power outages, and theft cuts help electric power operation and maintenance personnel to quickly find fault points and prevent the accident from further expanding.
◆ Improve the efficiency of corporate electricity use
The SL-ZPL-1000 power energy-saving intelligent control management system allows users to adopt electricity hosting and reduce labor costs.
The system has powerful automatic inspection and automatic fault alarm functions to avoid damage to electrical equipment and prolong the service life of electrical equipment. Greatly reduce the waste of investment in electrical equipment.
SL-ZPL-1000 intelligent control management system for electric energy saving provides enterprises with real and accurate power consumption data, which enables each production unit to establish a comprehensive assessment mechanism to prevent leaks and human waste. Allows enterprises to greatly reduce the cost of electricity management and save costs.
SL-ZPL-1000 power energy-saving intelligent control management system, as an enterprise power user-side management platform, implements data access with the government's power-demand-side management platform to enjoy government electricity price concessions and power policy support.

Functions of SL-ZPL-1000 Electric Energy Saving Intelligent Control Management System
◆ Automatic monitoring function
SL-ZPL-1000 intelligent control system for electric energy saving has a friendly human-machine interface, which can display the node status of the power distribution line in an intuitive form, meanwhile, it will collect the electrical parameter information of each circuit in real time, and the Opening and closing status and related faults, alarm signals, and real-time display in the system interface. Allow enterprise managers to understand the operation of the enterprise's electricity at a glance, and provide an effective basis for energy conservation of enterprises.

◆ Generate energy report
SL-ZPL-1000 intelligent control management system for electric energy saving reflects the integrity of the measurement system with rich data reports. The system has the functions of periodic meter reading and summary statistics for each loop, and users can freely query the power consumption of each main distribution node within any period of time since the normal operation of the system. Analyze the report. This function makes power consumption visible and transparent, and can be traced when the power consumption error is large, maintaining the correctness of the measurement system.

◆ Electricity running curve
The SL-ZPL-1000 electric energy-saving intelligent control management system records the power and load trends of the low-voltage main incoming circuit (or important load outgoing line) of the power distribution system. It is convenient for the distribution maintenance personnel to grasp the power demand and the proportion of the power supply system load in time to ensure the reliability of the power supply and provide protection for the energy consumption rights of the user unit. With this function, it is also possible to analyze the growth trend of energy demand, the power company's energy comparison assessment, load management, etc.

◆ Record real-time data
SL-ZPL-1000 electric energy-saving intelligent control management system has the functions of storage and management of real-time power parameters and historical power parameters. All real-time collected data and sequence event records can be saved to the real-time database. In the monitoring screen, you can customize the parameters you need to query, the time period of the query, or select the number of recently updated records, etc., and display them in a report mode. This function is convenient for users to trace accidents.

◆ Mobile reminder alarm
SL-ZPL-1000 electric energy-saving intelligent control management system has the function of remote signal alarm configuration. The system can monitor and alarm the opening and closing actions of the distribution circuit breaker in real time. When the system alarms, the phone can give voice prompts and automatically push the alarm screen.


◆ Engineer workstation
SL-ZPL-1000 power energy saving intelligent control management system can display the communication status of each device connected to the system in real time, can completely display the network structure of the entire system, can diagnose the network communication status of the system online, and can be automatically displayed on the screen when a network failure occurs The faulty unit and fault location are displayed. Therefore, it is convenient for the system maintenance personnel to grasp the communication status of each equipment on the site in real time, and perform timely maintenance on the abnormal equipment to ensure the stable operation of the system.

◆ Power quality analysis
The SL-ZPL-1000 power energy saving intelligent control management system combines offline with certain inspection methods, such as: quality statistical analysis, quality tracking, trend assessment, cross-line warning, power quality report, interactive quality data query, etc. Electric energy is quality-controlled in various energy media, balancing the contradiction between the quality of energy media and product costs.
Current trend graph


◆ User rights management
SL-ZPL-1000 electric energy-saving intelligent control management system has set up user rights management function to ensure the safe and stable operation of the system. User rights management can prevent unauthorized operations (such as changing the name of the power distribution circuit). You can define login names, passwords, and operation rights of users at different levels to provide reliable security for system operation and maintenance management.
The SL-ZPL-1000 power energy-saving intelligent control management system can divide the user's level into four levels: operator, squad leader, engineer, and general manager. Each level can be individually assigned to different operation permissions, including entering operation, exiting operation , Data query operation, report management. The system administrator is the highest-level user, and the higher-level user can add and delete the next-level user.

SL-ZPL-1000 power energy saving intelligent control management system and electric energy service integrated solution, analysis of eight common problems that enterprises are concerned about;
Eight major problems such as line loss, power factor, each line overcurrent, transformer over-temperature, transformer load matching, three-phase current and voltage balance, artificial waste or artificial power stealing behavior and harmonics , And automatically form electric energy minutes, hours, days, months, and years in the cloud data, automatic analysis, modeling, automatic inspection, automatic locking of fault points and alarms, timely processing of faults, reducing the business problems caused by the above problems The impact of normal production will escort the company's production safety.
Power intelligent control management system and power service integration solution

◆ Line loss
When a user enterprise is building a new project, in order to pursue the timeliness of production, it is often easy to ignore the cost-effectiveness of the high-voltage substation and distribution line construction, and it will blindly pursue the start of construction. As long as it can meet the general production needs, it will be used. Hidden dangers are buried in the safe use of the equipment. The normal range of the line loss value is: line loss value ≤5%. The SL-ZPL-1000 electric energy saving intelligent control management system collects loop measurement data online, calculates it through the background, and compares. Generate reports and store them in the cloud server at the same time, promptly remind users to check through the mobile phone, and at the same time find problems, solve problems, and ensure that enterprises use electricity and save energy.
◆ Causes of Line Loss
The line loss is generally caused by the following reasons: the transmission line is old and the wire diameter is too small to meet the maximum requirements for voltage and current to pass; the production load of the enterprise has soared, and the original wire load was too large.
◆ Consequences of Line Loss
The most direct loss caused by excessive line loss is the increase in the cost of electricity used by the company, the huge increase in electricity costs, and severe line loss will accelerate the life of the wire and drastically reduce the cost of the company. It will even cause a fire and burn the electrical equipment. Production interruption caused huge economic losses.
◆ Line loss solution
The SL-ZPL-1000 power energy saving intelligent control management system will notify the user via mobile phone when it finds a line loss problem during the self-inspection. According to the design standards and requirements of the SL-ZPL-1000 power energy saving intelligent control management system, it will provide Pertinent best optimization solutions, such as: replacement of wires, load control, etc.
◆ Power factor
In the process of using electricity, user companies often have low power factor due to the seasonality of production, the time difference when the load is turned on, or even the mismatch of the load. The normal range of power factor value is: cos∮≥0.9.
◆ Consequences of low power factor
● Power supply department fines
● The line loss of the power network has increased significantly, and the output capacity of electrical equipment has decreased, resulting in abnormal production.
● Increase in electricity expenses
◆ Low power factor solution
When the SL-ZPL-1000 power energy saving intelligent control management system finds a low power factor during the self-inspection process, it will remind users through mobile phones. According to the design standards and requirements of the SL-ZPL-1000 power energy saving intelligent control management system, It will provide the best targeted optimization schemes, such as: installing power capacitor cabinets for compensation, load control, and optimization of transformers.
◆ Each way
In the process of electricity use by users, because the line load is too large, there is no automatic monitoring system, and equipment over temperature, over voltage, over current, and overload are not found in time.
◆ Consequences of each pass
● Equipment is in dangerous operation, which is prone to equipment damage or greatly shortened service life.
◆ Over-current solution for each channel
SL-ZPL-1000 electric energy-saving intelligent control management system automatically monitors and manages uninterruptedly. It can timely detect the problem of overcurrent in each channel, allowing the enterprise to accurately grasp the current situation and prevent harm.
◆ Transformer over-temperature does not match transformer load
The user company had problems when designing the transformer capacity at the beginning, or problems caused by adjusting the load after the production volume increased.
◆ Results of mismatch between transformer overtemperature and transformer load
● Big Mara trolley will increase its damage and decrease its power factor.
● Small horse-drawn carts will increase the damage and reduce the life of the transformer. If the temperature exceeds the upper limit of 10 degrees, the life will be reduced by half.
● Electricity costs of enterprises increase, and production is not safe.
◆ Transformer over-temperature and transformer load mismatch solution
SL-ZPL-1000 power energy saving intelligent control management system will find out that the transformer over-temperature and the transformer load do not match during the self-inspection process, it will remind the user company to reduce the basic electricity cost by expanding or reducing the transformer, and ensure the most Optimal economic operation interval, maximize efficiency, and eliminate potential safety hazards.
◆ Three-phase unbalance
Due to improper electrician operation and unscientific wiring of electrical equipment, the user company's load on one phase is too large, and the load on each phase (air conditioner, water heater, computer lighting, etc.) is unbalanced, and three-phase imbalance will occur.
◆ Three-phase unbalanced consequences
● The output power of electrical equipment such as three-phase motors decreases, the motor overheats, the transformer working capacity decreases, and there is a large amount of neutral current in the circuit.
● A large amount of wire loss is caused, and the switch is easy to burn.
● Increase in electricity expenses
◆ Three-phase unbalanced solution
SL-ZPL-1000 power energy saving intelligent control management system found three-phase current and voltage imbalance during the self-inspection process. Through background modeling and analysis, it promptly reminded the user company, issued an early warning signal, let the company adjust, and provided energy saving Based on this, at the same time avoid electrical fires caused by three-phase imbalance, ensure the normal use of electrical equipment, and escort the safe and continuous production of enterprises.
◆ Serious harmonics <br /> In the production process, users use a lot of equipment (computers, inverters, electric arc furnaces, UPS power supplies) that change the common frequency, or the power is too large, causing a lot of harmonics.
◆ Harmonic consequences
● Capacitor equipment is overheated and burned, and the terminal is accelerated to oxidize, resulting in poor contact.
● The meter reading is inaccurate, and the relay malfunctions.
● Reduce power factor, increase line loss, change loss, etc.
● Electrical equipment is too noisy, vibration, electromagnetic pollution.
● Electricity expenses increase (harmonics plus 5%, line loss doubles).
◆ Harmonic solution
SL-ZPL-1000 power energy saving intelligent control management system will detect the harmonic problems during the self-inspection process, and will send a reminder signal through the mobile phone APP to let the company know in time, through the installation of filters and other related equipment, to control harmonic To ensure the normal use of precision instruments, reduce the investment cost of precision instruments, and increase productivity.
◆ Unscientific or missing electricity management
The user company does not have an automatic monitoring system or an electrician. At the same time, it is unscientific in power management. There is even “running, running, leaking, dripping” or stealing electricity or human waste.
◆ Consequences:
● The motor is idling (up to 60% -70% reactive power consumption). The transformer is no-load or too low load (reactive power is 3 times of full load).
● Each household's electricity monitoring in the living area, the school monitors the electricity consumption of the student dormitory.
● Electricity expenses increased.
● Pay more for electricity and increase production costs.
◆ Unscientific electricity management or missing solutions
Install SL-ZPL-1000 power energy saving intelligent control management system, through the system's uninterrupted self-inspection, self-inspection, through the system's multi-functional report, modeling analysis, monitoring and protection of each link of power consumption, to achieve scientific Management, scientific power consumption, energy-saving visualization of power consumption, improve corporate energy efficiency, and escort corporate energy-saving production.

SL-ZPL-1000 Electric Energy Saving Intelligent Control Management System Eight Application List

Copyright 2016 All Rights Reserved. Jiangxi Silian Energy Saving and Environmental Protection Co., Ltd. All rights reserved